Configuring the emu, Connecting the emu communication bus, Figure 3–4 emu communications bus connections – HP Array Controller HSG V8.7 Software User Manual

Page 63: Figure 3–4 emu communications bus connections –7

Advertising
background image

Environmental Monitoring Unit

UltraSCSI RAID Enclosure 3–7

Configuring the EMU

Configuring the EMU requires connecting the EMU-EMU
communications bus and using the command line interpreter (CLI)

set emu

command. This command establishes operating

temperature set points and desired blower speed operating mode
(high-speed or automatic).

Connecting the EMU Communication Bus

In an expansion configuration, an EMU-EMU communications bus
between the master EMU and each expansion EMU must be
established. To establish this communications bus, connect the EMU
communications connector using a BN26M series cable, as shown in
Figure 3–4. The center EMU in this figure is the master EMU.
Establishing this EMU-EMU communication bus ensures that the
master EMU can monitor and control all the enclosures within the
UltraSCSI subsystem.

Figure 3–4

EMU Communications Bus Connections

Compaq recommends using a BN26M cable (see Table 3–1) no
longer than 4 m (13.1 ft) to connect the EMUs.

CXO5820A