Command device, Pprc specifications, restrictions – HP XP P9500 Storage User Manual

Page 17

Advertising
background image

Table 4 SAID values for PATH LINK (CL2) (continued)

SAID

Port

Package
Local

SAID

Port

Package
Local

SAID

Port

Package
Local

SAID

Port

Package
Local

-

-

-

-

X'001F'

CL2-R

X'0017'

CL2-H

-

-

-

-

X'003F'

CL4-R

X'0037'

CL4-H

-

-

-

-

X'005F'

CL6-R

X'0057'

CL6-H

-

-

-

-

X'007F'

CL8-R

X'0077'

CL8-H

Command device

Business Continuity Manager requires a command device on the Continuous Access Synchronous
Z disk array that is independent of the command device for an open system. The command device
for BCM can be configured only from BCM.

To find the command device using Remote Web Console:
1.

In Remote Web Console, click File/Reports. The Report Display window displays.

2.

Click the LDEV tab.

If you are using XP12000 Disk Array/XP10000 Disk Array, only the volumes with a CU: LDEV
number between 00: 00 to 3F: FF can be used as command devices.

F/M = FB message output control option when operating R-VOLs

When the suspension or the release operation is performed from Business Continuity Manager
(BCM) to the R-VOL of Continuous Access Synchronous Z pair in the Duplex status, the status of
the M-VOL becomes Suspend and the F/M = FB message is output to the host connected to MCU.
You can control the output of this message by setting the system option mode 776.

However, even if the system option mode 776 is set, the F/M = FB message is output when the
pair status becomes Suspend due to the failure. Moreover, the F/M = FB message is not output
regardless of the setting of system option mode 776 if PPRC support by host = No is selected on
the CU Option dialog box.

Table 5 Whether to output the F/M = FB message when operating R-VOLs

Settings

Cause of the
suspension of M-VOL

The system option mode 776 is OFF

The system option mode 776 is ON

PPRC support by host
= No

PPRC support by host
= Yes

PPRC support by host
= No

PPRC support by host
= Yes

No

Yes

No

No

Suspended by the
suspension or the
release operation from
BCM to R-VOLs

No

Yes

No

Yes

Suspended by failure

PPRC specifications, restrictions

Most Continuous Access Synchronous Z operations can be performed using PPRC TSO or ICKDSF
PPRCOPY commands from the host system console. All P9500 systems support IBM PPRC host
software functions.

PPRC specifications, restrictions

17