The Basic HyperSwap function performed from TPC-R may fail, when the FREEZE command process
does not complete within 20 seconds. We recommend the following conditions to complete the
FREEZE command process within 20 seconds.

•

(Number of Host paths) x (Number of LPARs) x (Number of CGROUPs (Number of CUs)) ≤
160

•

Number of pairs ≤ 4,096

Figure 3 Configuration of Cnt Ac-S Z synchronous pair M-VOLs and R-VOLs using TPC-R

Cache failure

When a cache failure occurs on the storage system, recover the cache failure, and then
resynchronize the Cnt Ac-S Z pair from TPC-R. Resynchronizing the Cnt Ac-S Z pair before recovering
the cache failure causes the resynchronization to fail. In this case, TPC-R issues a pair-deletion
command and resynchronizes the Cnt Ac-S Z pair automatically. All data in the M-VOL is recopied
to the R-VOL.

Unregistered error code for TPC-R

When using Basic HyperSwap, an unregistered error code for TPC-R might be displayed. In this
case, recover the Cnt Ac-S Z pair using the method described in the following table.

Table 9 Unregistered error code for TPC-R

Recovery procedure

Description

Operation

Error code

Remove the failure on the
cache, and then retry the Cnt
Ac-S Z pair creation operation.

The Cnt Ac-S Z pair creation failed because
it was executed when a failure occurred in
the cache.

Pair creation

0F0E

Remove the failure in the
cache, and then retry the Cnt

The Cnt Ac-S Z pair resynchronization
operation failed because it was executed

Pair
resynchronization

Ac-S Z pair resynchronization
operation.

when a failure occurred in the cache.
Although the Cnt Ac-S Z pair is deleted and
recreated (a whole copy) by the recovery
operation of TPC-R from the Cnt Ac-S Z pair
resynchronization failure, the recovery
operation fails.