HP StorageWorks 500 Modular Smart Array User Manual
Page 103

Display Messages
HP StorageWorks Modular Smart Array 500 System User Guide
C-11
Table C-1: Display Messages
continued
Message Type
Description Action
50 REDUNDANCY
FAILED OUT OF
MEMORY
Error While
either attempting
to enter redundant mode
or already operating in
redundant mode, one of
the array controllers
failed to allocate required
memory. Redundancy is
disabled at this time.
If the MSA500 system is
currently involved in host
I/O:
1.
Remove the standby
array controller.
2.
Wait 10 seconds.
3.
Reinsert the controller,
and be sure that it
seats fully in the
chassis.
If this action does not solve
the problem, wait until
downtime is available and
do the following:
1.
Power down the
MSA500 system.
2.
Remove both array
controllers.
3.
Reinstall both array
controllers, and be sure
that they seat fully in
the chassis.
If this action does not solve
the problem, contact HP
support.
continued