Hot-plug scsi hard drive led combinations, Hot-plug scsi hard drive led combinations -17 – HP StorageWorks 500 Modular Smart Array User Manual
Page 28

Component Identification
HP StorageWorks Modular Smart Array 500 System User Guide
1-17
Hot-Plug SCSI Hard Drive LED Combinations
Table 1-12: Hot-Plug SCSI Hard Drive LED Combinations
Activity
LED
Online
LED
Fault
LED
Status
On Flashing
Off Do not remove the drive. Removing a drive during this
process can cause data loss in non-fault-tolerant
configurations.
•
The drive is a replacement drive and is being rebuilt or
•
If all online LEDs in a drive array are flashing, an
expansion is occurring.
Off
Off
On
OK to replace the drive online.
The drive has failed and has been placed offline.
Off, on, or
flashing
On Off Do not remove the drive. Removing a drive during this
process can cause data loss in non-fault-tolerant
configurations.
The drive is online and configured as part of an array.
Off, on, or
flashing
On or Off
Flashing
A predictive failure alert has been received for this drive.
Replace the drive as soon as possible.