HP StorageWorks 500 Modular Smart Array User Manual
Page 127

Display Messages
HP StorageWorks Modular Smart Array 500 System User Guide
C-35
Table C-1: Display Messages
continued
Message Type
Description Action
305 ROM CLONING
FAILED
Error
Indicates that the two
array controllers in a
MSA500 system failed
the firmware cloning
process.
1.
Remove the failing
array controller.
2.
Wait 10 seconds.
3.
Reinstall the array
controller, and be sure
that it seats fully in the
chassis.
The controller reattempts
the controller firmware auto
cloning process again.
If this action does not solve
the problem, contact HP
support.
306 FIRMWARE
FLASH STARTED
Informational
Indicates that the array
controller in the MSA500
system is flashing the
firmware.
Do not power down the
system until the process is
complete.
The process could take up
to 5 minutes.
307 FIRMWARE
FLASH DONE
Informational
Indicates that the array
controller in the MSA500
system completed the
firmware flash process.
Power down the system.
308 FIRMWARE
FLASH FAILED
Error
Indicates that the array
controller in the MSA500
system failed the
firmware flash process.
Attempt the flash process
again.
If this action does not solve
the problem, contact HP
support.
continued