HP StorageWorks 500 Modular Smart Array User Manual
Page 106

Display Messages
C-14
HP StorageWorks Modular Smart Array 500 System User Guide
Table C-1: Display Messages
continued
Message Type
Description Action
54 REDUNDANCY
FAILED CACHE
DIMMS MISMATCH
Error
The cache memory
modules on two different
controllers are not the
same size. All cache
memory modules must
be the same size for
redundant mode.
1.
Remove the array
controller that has
halted.
2.
Replace the cache
memory with the
appropriately sized
DIMMs.
3.
Wait 10 seconds.
4.
Reinstall the array
controller, and be sure
that it seats fully in the
chassis.
60 NO CACHE
MODULE FOUND
Error
The array controller
requires at least one
cache module in order to
operate. The cache
module is not present or
it has failed.
1.
Remove the failed array
controller.
2.
Either add a cache
module or replace the
failed one.
3.
Wait 10 seconds.
4.
Reinstall the array
controller, and be sure
that it seats fully in the
chassis.
If this action does not solve
the problem, contact HP
support.
continued