Appendix c: display messages, Appendix c, Display messages – HP StorageWorks 500 Modular Smart Array User Manual
Page 93

HP StorageWorks Modular Smart Array 500 System User Guide
C-1
C
Display Messages
The display message may specify a box number. Box 1 is the MSA500 system
chassis.
Table C-1 defines display messages and provides the appropriate response, if action
is required.
Table C-1: Display Messages
Message Type
Description Action
00 ARRAY
CONTROLLER
FIRMWARE VER
<version>
Informational
Displays the current
version of the firmware
running on the array
controller.
—
01 HP SMART
ARRAY CL
STARTUP
COMPLETE
Informational
The array controller
completed its power up
sequence and is now
operational.
—
02 ENABLE VOLUME
<n>? ‘<’=NO, ‘>’=YES
User Input
An issue exists with a
configured volume that
may result in data loss.
Refer to display
messages for more
information.
Selecting no or not
selecting any option within
the timeout period causes
the controller to disable the
volume, so the user can
attempt to fix the issue.
Selecting yes causes the
controller to enable the
volume regardless of the
issue.
continued