HP StorageWorks 500 Modular Smart Array User Manual
Page 24

Component Identification
HP StorageWorks Modular Smart Array 500 System User Guide
1-13
Table 1-9: Controller LEDs
continued
Item LED
Descriptions Status
11
Logical I/O activity
Green = Currently processing logical
requests from the host adapter.
Off = No processing of logical requests
12
SCSI bus 0 activity
13
SCSI bus 1 activity
Green = Outstanding requests on the
SCSI bus
Off = No outstanding requests
14
Cache activity
Green = Cache activity
Off = No cache activity
Flashing green = Cache transfer pending
15
Drive failure
Green = An array-configured drive has
failed.
Off = No drive failures
16
Active redundancy
Green = Controllers are operating with
redundancy.
Off = No redundancy
17
Fault
Amber = Error message received by
controller display.
Off = No error message received or no
error message currently displayed.