HP StorageWorks 500 Modular Smart Array User Manual
Page 124

Display Messages
C-32
HP StorageWorks Modular Smart Array 500 System User Guide
Table C-1: Display Messages
continued
Message Type
Description Action
202 ARRAY
CONTROLLER
OVERHEATING
Error
The temperature sensor
on the array controller
indicates that the array
controller is exceeding
the normal operating
range.
1.
Be sure that all
MSA500 system fans
are operating.
2.
Replace any failed
fans.
3.
Be sure that all bays
are populated with
components or blanks.
If this action does not solve
the problem, contact HP
support.
203 ARRAY
CONTROLLER
OVERHEATED
Error
The temperature sensor
on the array controller
indicates that the array
controller exceeded the
safe operating range.
1.
Power down the
MSA500 system as
soon as possible to
avoid hardware failure.
2.
Be sure that all
MSA500 system fans
are operating.
3.
Replace any failed
fans.
4.
Be sure that all bays
are populated with
components or blanks.
If this action does not solve
the problem, contact HP
support.
continued