Display Messages
HP StorageWorks Modular Smart Array 500 System User Guide
C-29
Table C-1: Display Messages
continued
Message Type
Description Action
121 NO VOLUMES
DETECTED
Informational
The controller did not
detect configured
volumes at power up.
If configured volumes are
expected at power up:
1.
Power down the
MSA500 system.
2.
Power down all
attached storage
enclosures.
3.
Remove and reinstall
all SCSI drives, and be
sure that they seat fully
in their bays.
4.
Check for proper
connections on the
cables between the
MSA500 system and
any attached storage
enclosures.
5.
Power up the attached
storage enclosures.
6.
Power up the MSA500
system.
If this action does not solve
the problem, contact HP
support.
122 NEW
VOLUME(S)
DETECTED
Informational
Configured volumes from
another array controller
were migrated to this
array controller. The
controller updated the
configuration information.
—
continued