HP StorageWorks 500 Modular Smart Array User Manual
Page 129

Display Messages
HP StorageWorks Modular Smart Array 500 System User Guide
C-37
Table C-1: Display Messages
continued
Message Type
Description Action
402 STORAGE BOX
#<n> FAN
DEGRADED
Error
The specified storage
enclosure indicates that
one of its fans is not
operating at full
efficiency. The fan may
eventually fail.
1.
Be sure that all
MSA500 system fans
are operating.
2.
Replace any failed
fans.
If this action does not solve
the problem, contact HP
support.
403 STORAGE BOX
#<n> FAN HOT
INSERTED
Informational
The specified storage
enclosure indicates that
a fan was added.
—
404 STORAGE BOX
#<n> FAN HOT
REMOVED
Informational
The specified storage
enclosure indicates that
a fan was removed.
—
405 STORAGE BOX
#<n>
TEMPERATURE OK
Informational
The temperature sensor
in the storage enclosure
indicates that the
temperature is in the
normal operating range.
—
continued