HP StorageWorks 500 Modular Smart Array User Manual
Page 116

Display Messages
C-24
HP StorageWorks Modular Smart Array 500 System User Guide
Table C-1: Display Messages
continued
Message Type
Description Action
104 VOLUME #<n>
STATE DISABLED
Error The
controller
disabled
the configured volume
because too many of the
physical drives that
constitute the volume are
missing.
1.
Power down the
MSA500 system.
2.
Power down all
attached storage
enclosures.
3.
Remove and reinstall
all SCSI drives, and be
sure that they seat fully
in their bays.
4.
Check for proper
connections on the
cables between the
MSA500 system and
any attached storage
enclosures.
5.
Power up the attached
storage enclosures.
6.
Power up the MSA500
system.
If this action does not solve
the problem, contact HP
support.
105 VOLUME #<n>
STATE EXPANSION
ACTIVE
Informational
The configured volume is
performing a volume
expansion operation.
—
continued