HP StorageWorks 500 Modular Smart Array User Manual
Page 120

Display Messages
C-28
HP StorageWorks Modular Smart Array 500 System User Guide
Table C-1: Display Messages
continued
Message Type
Description Action
112 VOLUME #<n>
REBUILD FAILURE
Error
The rebuild operation on
the configured volume
failed.
If the volume is still
operating in regenerative
mode, remove the
replacement drive and
replace it with a different
new drive.
113 VOLUME #<n>
EXPANSION
FAILURE
Error
The volume expansion
operation on the
configured volume failed.
Run ACU and determine the
state of the volume. If the
volume is still operational,
reattempt the operation.
114 VOLUME #<n>
STATE DELETED
Informational
The configured volume is
deleted and no longer
available. Use ACU to
delete volumes.
—
120 CONFIGURED
VOLUMES <n>
Informational The
controller
detected
the specified number of
configured volumes at
power up.
—
continued