Change mirror option dialog box – HP XP P9500 Storage User Manual

Page 154

Advertising
background image

Description

Item

Applies the settings in the dialog box to the Journal Operation window

Set

Cancels the settings and closes the dialog box.

Cancel

Change Mirror Option dialog box

This dialog box lets you change the options of a mirror.

Description

Item

Restrict inflow of update data to the journal volume. Yes restricts inflow, No does not restrict.
(slows delay response to hosts

Inflow Control

Sets number of seconds for the system to monitor write data to the journal volume, after the
journal volume threshold (80%) is reached.

Data Overflow Watch

Stores journal data in cache memory from the restore journal (only).

Use of Cache

Sets the type of clock used for consistency time—System, Local, None.

Timer Type

Sets unit of time for Path Watch Time—minute, hour, or day.

Unit of Path Watch
Time

Specify the interval from when a path gets blocked to when a mirror gets split (suspended).

Path Watch Time

This value must be within the range of 1 to 59 minutes, 1 to 23 hours, or 1 to 30 days. You
can specify a numeric value in Path Watch Time.

Make sure that the same interval is set to both the master and restore journals in the same
mirror, unless otherwise required. If the interval differs between the master and restore journals,
these journals do not suspend simultaneously. For example, if the interval for the master journal
is 5 minutes and the interval for the restore journal is 60 minutes, the master journal suspends
in 5 minutes after a path gets blocked, and the restore journal suspends in 60 minutes after
a path gets blocked.

Important: If you want a mirror to get split (suspended) immediately after a path gets blocked,
ask HP Technical Support to set the system option mode 448 to ON and set the system option
mode 449 to OFF.

Forwards the Path Watch Time value for the master journal to the restore journal, which results
in the same Path Watch Time value for both.

Forward Path Watch
Time

Sets pace for initial copy—Slow, Medium, or Fast.

Copy Pace

Line speed of data transfer.

Transfer Speed

154 Continuous Access Journal Z GUI reference