limits the distance that the robot can travel. If the library floor is attached to the base module, the bottom

two rows (containing 16 slots) cannot be used.
The robotics unit is located at the top of the base module. When fully retracted (or parked), the robot

is fully contained within a 2U space. For safety reasons, the robot is parked before the center door

can be opened.
Within the robot, a lift table assembly contains a motor, pulleys, and cables to move the table up and

down to a desired level in the library. The picker assembly moves front and back, and side-to-side along

the table. A bar code scanner, attached to the bottom of the picker assembly, scans targets on rack

components for alignment, as well as bar code labels on tape cartridges, if they are present. The picker

has fingers that remove and insert tape cartridges among storage slots, tape drives, or load ports.

gl01029

1

8

2

3

4

5

6

7

1

Robotics unit

5

Lift suspension cable

2

Lift-flex retraction handle

6

Table assembly

3

Ratchet tool

7

Lift pole

4

Robot picker

8

Lift-flex cable

Figure 3 Robotics unit

The base module has two windows on the front for viewing the robotic motion inside the library. A load

port door is located to the right front (see

Figure 1

on page 19) where a 5-cartridge magazine can be

loaded with tape cartridges for insertion into or removal from the library. The load ports are mechanical

devices that enable you to import and export tape cartridges to and from the library through removable

magazines, or act as additional library storage slots. These two functions for a load port cannot be

mixed; you must either designate an entire load port to be import/export slots or storage slots. The base

module contains a load port capable of using one 5-cartridge magazine. An operator control panel

(OCP) is located at the bottom front of the base module.
The base module contains an autoranging power supply (a redundant power supply is optional), card

cage, cable management features, and space for mounting up to four LTO-technology tape drives on the

back.
The card cage in the base module (see

Figure 4

on page 22) provides six cPCI slots for the following:

Enterprise Modular Library E-Series

21