4 removing and replacing parts, Library robotics controller, Required tools – HP EML E-series Tape Libraries User Manual

Page 81: Removing the library robotics controller

Advertising
background image

4 Removing and replacing parts

This chapter provides information for the removal and replacement of each expansion module and

field replaceable unit (FRU).

CAUTION:

Components within the library contain static-sensitive parts. Use appropriate ESD precautions, including

the use of a grounding strap, when performing service inside the library. For more information, see

Taking ESD precautions

” on page 12.

Library robotics controller

Part Number

375814-001 or 435891-001

Location

Top slot in the base-module card cage

Characteristics

Contains one Ethernet connection to the Interface Manager card

Function

Controls the movement of the library robotics

Illustration

10462

Required tools

#1 Phillips screwdriver

Removing the library robotics controller

1.

Use your backup software to stop all library activity and make sure the picker is empty.

2.

Turn off the power to the library.

3.

Identify the library robotics controller in the top slot in the card cage in the base module.

4.

Label the cables or write a note that shows the locations of all the cables plugged into the library

robotics controller to make it easier to reconnect them later.

5.

Unplug all cables from the library robotics controller.

6.

Loosen the captive screws in the ejector handles at both ends of the library robotics controller.

Use a #1 Phillips screwdriver.

7.

Push in the red tabs on the ejector handles and push the ejector handles to the outside.

8.

Pull the ejector handles to remove the library robotics controller from the library.