Hp storageworks interface manager card, Required tools, Removing the interface manager card – HP EML E-series Tape Libraries User Manual

Page 83

Advertising
background image

HP StorageWorks Interface Manager card

Part Number

342213-001 or 393531-001

Location

Bottom slot in the base-module card cage

Characteristics

Contains six Ethernet connections to the library robotics controller,

four interface controllers, and the SAN; two 3-pin serial ports;

status, activity, and error LEDs

Function

Manages the interface controllers in order to monitor and

manage the library

Illustration

10463

Required tools

#1 Phillips screwdriver

Removing the Interface Manager card

1.

Use your backup software to stop all library activity and make sure the picker is empty.

2.

Turn off the power to the library.

3.

Identify the Interface Manager card. It is located in the bottom slot in the card cage in the base

module.

4.

Label the cables or write a note that shows the locations of all the cables plugged into the Interface

Manager card to make it easier to reconnect them later.

5.

Unplug all cables from the Interface Manager card.

6.

Loosen the captive screws in the ejector handles at both ends of the Interface Manager card. Use a

#1 Phillips screwdriver.

7.

Push the ejector handles to the outside.

8.

Pull the ejector handles to remove the Interface Manager card from the library.

Enterprise Modular Library E-Series