target AutoPATH_ID is 000000, enter 000000 or 0 for the parameter

value.
AutoPATH_IDs are re-assigned every time the host is restarted. When you

want to add a new LU without restarting the host, AutoPATH_IDs are re-

assigned to each path of the LU when you execute the HDLM-

configuration definition utility (dlmcfgmgr). Always make sure that you

use the view operation to find the current AutoPATH_ID of the target

path, before executing the online operation.

Example

The following example shows how to place online the paths connected

to the CHA port 0A. In this example, a path whose AutoPATH_ID is
000002 is connected to the target CHA port:
When the confirmation message is displayed, the user enters y to

continue, or n to cancel the operation.

# /opt/DynamicLinkManager/bin/dlnkmgr online -cha -pathid

000002

KAPL01057-I All the paths which pass the specified CHA port

will be changed to the Online status. Is this OK? [y/n]:y

KAPL01061-I 2 path(s) were successfully placed Online; 0

path(s) were not. Operation name = online

#

-pathid AutoPATH_ID

Use this parameter to place a single path online.
Specify the current AutoPATH_ID of the target path, which is displayed by

using the view operation. For details about the view operation, see

view

(Displays Information) on page 6-30

. Leading zeros can be omitted

(000001 and 1 indicate the same AutoPATH_ID); however, when the

target AutoPATH_ID is 000000, enter 000000 or 0 for the parameter

value.
AutoPATH_IDs are re-assigned every time the host is restarted. When you

want to add a new LU without restarting the host, AutoPATH_IDs are re-

assigned to each path of the LU when you execute the dlmcfgmgr utility.

Always make sure that you use the view operation to find the current

AutoPATH_ID of the target path, before executing the online operation.

-device SCSI-device-name

Use this parameter to place online a path connected to the specified SCSI

device.
For SCSI-device-name, specify the value of Device displayed by

executing the view operation as follows:
# /opt/DynamicLinkManager/bin/dlnkmgr view -lu
For details on how to execute the view operation and display the SCSI

device name, see

To display LU information on page 6-51

in

Parameters

(To display program information) on page 6-32

. Only one case-sensitive

parameter value can be specified.

Example

6-12

Command Reference

Hitachi Dynamic Link Manager User Guide for Linux

®