Place two screws (10-32 Pan 0.625 XRCS) through the two holes at the back of the
C-Shelf, through the slide plate slots and loosely into the front two threaded holes of the
nut plate.

e.

Repeat steps a through d with the opposite hand slide bracket.

2.

Install the C-Shelf assembly into the rack:
a.

Locate a clear 1U area space within the rack.

NOTE:

The 1U space in a rack includes three rail mounting holes; however, the rack

holes are not evenly spaced. For best installation the C-Shelf can be centered in a 1U
space. To locate the center, find a hole that is 5/8" on center from the hole immediately
above and below. The two holes above and below this center are only 1/2" on center
from their adjacent holes.

b.

At the front of the rack, in the center mounting holes, install two nuts (KEPs 10-32, 0.375AF
CSZ EXT).

c.

Carefully supporting the C-Shelf assembly, loosely thread the knurled thumbscrews through
the rack into the two nuts just installed.

d.

Go to the back of the rack and position a slide bracket next to the corresponding holes
at the back of the rack. Slide the bracket to the rear until the threaded screw hole tabs
are flush with the inside of the rack rail.

e.

Insert two screws (10-32 Pan 0.325 XRCS screws) through the rack rail into the threaded
screw hole tab and tighten loosely.

f.

Repeat step e with the other side of the C-Shelf assembly.

g.

Tighten all four screws (10-32 Pan 0.625 XRCS screws) at the rear of the C-Shelf assembly.

h.

Tighten the front two knurled thumbscrews.

i.

Tighten the two screws (10-32 Pan 0.625 XRCS screws) at each side of the back of the
C-Shelf assembly.

3.

Install the mpx110 into one of the two available positions in the C-Shelf:
a.

As the mpx110 slides in there are two tabs at the front and rear that catch and ensure
that the mpx110 is firmly seated to the C-Shelf assembly. Take care to ensure that the
mpx110 is engaged in all four tabs. To ensure that all four of the tabs engage, you may
need to hold both the mpx110 and the C-Shelf assembly as you slide it in the last inch.

NOTE:

The front of the mpx110 is the end with the connections and faces the rear of

the equipment rack. The mpx110 slides in from the front of the equipment rack.

b.

Once the rear of the mpx110 is flush with the front of the C-Shelf assembly and all four
clips are engaged, the bezel can be snapped on the front.

Installing the SFPs

You will need an SFP transceiver for each of the FC ports that connect to an FC switch.

To install the SFPs:

1.

Align the SFP transceiver so that the key is oriented correctly to the port. Transceivers are
keyed so that they can only be inserted one way.

2.

Insert the transceiver into the port.

3.

Press gently until the transceiver snaps into place.

Management

The GUI application and CLI execute on a management workstation that provides for the
configuration, control, and maintenance of the mpx110. Supported platforms include Microsoft
Windows, Solaris, and Linux. The GUI application is installed and executed on the workstation.