Moving Storagesets
You can move a storageset from one subsystem to another without
destroying its data as shown in Figure 3–20. You also can follow the
steps in this section to move a storageset to a new location within the
same subsystem.
Caution Move only normal storagesets. Do not move storagesets that
are reconstructing or reduced, or data corruption will result.
You can use the procedure in this section to migrate wide devices from
an HSZ70 controller in a BA370 rack-mountable enclosure to an
HSG80 environment. However, if you have an HSZ40 or HSZ50
subsystem, you cannot migrate to an HSG80 in a BA370 rack-
mountable enclosure. Refer to the HSG80 Array Controller ACS
Version 8.2G Release Notes for drives that can be supported.
Figure 3–20
Moving a Storageset from one Subsystem to Another
Caution Never initialize any container or this procedure will not
protect data.
Use the following procedure to move a storageset while maintaining the
data it contains: