Last failure reporting – HP Array Controller HSG V8.7 Software User Manual
Page 169

Troubleshooting
4–15
Last Failure Reporting
Last Failures are displayed on the maintenance terminal using %LFL
formatting. The example below details an occurrence of a Last Failure
report:
In addition, Last Failures are reported to the host error log using
Template 01, following a reboot of the controller. See Figure D–2
“Template 01 - Last Failure Event Sense Data Response Format,” on
page D–4, for a more detailed explanation.
Events that do not cause controller operation to terminate
Events that do not cause controller operation to terminate are displayed
in one of two ways:
n
Spontaneous Event Log
n
CLI Event Reporting
%LFL--HSG> --13-JAN-1946 04:39:45 (time not set)-- Last Failure Code: 20090010
Power On Time: 0.Years, 14.Days, 19.Hours, 58.Minutes, 42.Seconds
Controller Model: HSG80
Serial Number: AA12345678 Hardware Version: 0000(00)
Software Version: V080G(50)
Informational Report
Instance Code: 0102030A
Last Failure Code: 20090010 (No Last Failure Parameters)
Additional information is available in Last Failure Entry: 1.