HP Array Controller HSG V8.7 Software User Manual
Page 176

4–22
HSG80 User’s Guide
SET FAULT_LED_LOGGING
SET NOFAULT_LED_LOGGING
enable and disable the solid fault LED event log display on the local
terminal. Preceded by “%FLL.” By default, logging is enabled (SET
FAULT_LED_LOGGING).
When enabled, and a solid fault pattern is displayed in the OCP
LEDs, the fault pattern and its meaning are displayed on the
maintenance terminal. For many of the patterns, additional
information is also displayed to aid in problem diagnosis.
In cases of automatic hardware reset (for example, power failure or
pressing the controller’s reset button), the fault LED log display is
inhibited because automatic resets do not allow sufficient time to
complete the log display.
SHOW PARAMETERS
displays the current settings associated with the SET command.
SET command PERMANENT
preserves the SET command across controller resets.
Table 4–3
FMU SET Commands (Continued)
Command
Result