Installing a Cache Module in a Dual-Redundant
Controller Configuration
Use the following steps to install a cache module:
1. Connect a PC or terminal to the operational controller’s maintenance
port. The controller to which you’re connected is “this controller”; the
controller that you’re installing is the “other controller.”
2. Start FRUTIL with the following command:
RUN FRUTIL
FRUTIL displays the following:
Do you intend to replace this controller’s cache battery? Y/N
3. Enter N(o). FRUTIL displays the FRUTIL Main menu:
FRUTIL Main Menu:
1. Replace or remove a controller or cache module
2. Install a controller or cache module
3. Replace a PVA module
4. Replace an I/O module
5. Exit
Enter choice: 1, 2, 3, 4, or 5 ->
4. Enter option 2, Install a controller or cache module, from the FRUTIL
Main menu. FRUTIL displays the Install Options menu:
Install Options:
1. Other controller and cache module
2. Other controller module
3. Other cache module
4. Exit
Enter choice: 1, 2, 3, or 4 ->
5. Enter option 3, Other cache module, from the Install Options menu.
FRUTIL display the following:
Insert the slot A [or B] cache module? Y/N