B–135
REPLACE=disk-name
Instructs the controller to add a disk member to an existing RAIDset if
the following conditions are met:
n
The replacement policy is set to NOPOLICY.
n
The disk member is not in any configuration, including a spareset.
An error is displayed and the command is rejected if the RAIDset is not
in a reduced state, if a replacement policy is already specified, or if the
disk specified is already being used by a configuration (including a
spareset).
Note Do not specify other switches when you use the REPLACE=
switch.
Examples
This example shows how to change the replacement policy for RAIDset
RAID9 to BEST_FIT:
SET RAID9 POLICY=BEST_FIT
This example shows how to remove member DISK10000 from the
RAID9 RAIDset:
SET RAID9 REMOVE=DISK10000
If there is a replacement policy, the controller moves a disk from the
spareset to the RAIDset automatically.
This example shows how to add disk DISK20100 to the reduced
RAIDset, RAID9:
SET RAID9 REPLACE=DISK20100
Reconstruction immediately begins on DISK20100.
See also