Operations 42

All existing logical drives in the source array must be in OK state.

The destination array must have sufficient capacity to hold all logical drives present in the source array.

Setting Auto RAID 0

CAUTION:

If you select this option for any logical drives, you will experience data loss for that

logical drive if one physical drive fails. Assign RAID 0 to drives that require large capacity and

high speed, but pose no data safety risk.

Auto Array RAID 0 creates a single RAID 0 volume on each physical drive specified, enabling the user to
select multiple drives and configure as RAID 0 simultaneously. Each array contains one physical drive and

one RAID 0 logical drive.
For more information about RAID 0, see "RAID 0—No fault tolerance (on page

109

)."

To create an array with RAID 0:

1.

Open HP SSA.
For more information, see "Using the HP SSA GUI (on page

16

)."

2.

Select the controller.

3.

Click Create Arrays with RAID 0.