Operations 95

Error code Error message

Comment or clarification

combining -reset with capture mode.

2818

Invalid Method

The method must be either Custom or Auto.

2819

Invalid Controller

An invalid controller value was specified.

2821

No controllers detected

No controllers were detected. This error applies to

Input mode only.

2823

Invalid Rebuild Priority

The specified rebuild priority is not supported.

2824

Invalid Expand Priority

The specified expand priority is not supported. This

error also occurs if the controller does not allow

expansion, and therefore does not support expand
priority.

2826

Array not specified

The Array command is missing from the script file.

Some commands were found that require an Array

to be specified.

2827

New Array ID does not match the next
available Array ID

The array ID in the script file does not match the
array ID of the next available array. For example, if

the configuration has an Array A and the input file

specifies Array C (without Array B), then the script
generates this error.

2828

New Array ID already exists

The array ID specified in the script file (in Configure

mode) already exists in the configuration. Configure

mode can only create new arrays.

2829

Cannot create Array

The controller will not allow a new array to be

created, either because the controller has no

unassigned physical drives attached or because the
maximum number of arrays or logical drives has

been reached already.

2830

Cannot expand Array

The Array could not be expanded, either because

the controller does not support expansion, or the
current configuration does not allow expansion to

occur on the array.

2831

Cannot change Array Spare

The spare state of the array could not be changed.

This error can occur when you attempt to add or
drop a spare and the current configuration does not

allow a spare state change for the array.

2832

Invalid physical drive. Possible reasons for
this include: a typing error, the drive already

exists in an array, the drive type does not

match, or it is a failed drive.

A specified physical drive is not a valid physical
drive, or it cannot be placed in the array.

2833

Invalid Spare

A specified spare is not a valid spare drive, or it

cannot be placed in the array as a spare.

2834

Invalid logical drive

The logical drive ID is not valid.

2836

New Logical Drive ID does not match the

next available logical drive ID.

If you are attempting to replicate a
configuration that has non-consecutive

logical drive numbers, then you must

change the script file so that the logical drive

numbers are consecutive.

The script file specifies a logical drive ID that is not

the first unused ID in the sequence. For example, this

message appears if the controller has only Logical
Drive 1 and the script file specifies creation of

Logical Drive 3 (omitting Logical Drive 2). A common

cause of this error is that the input file specifies

nonsequential logical drive numbers. In this case,
change the logical drive numbers in the input file so

that they are sequential.

2837

New Logical Drive ID already exists

This error occurs in Configure mode when the logical