background image

Operations 96

Error code Error message

Comment or clarification

drive ID specified in the script file already exists in

the configuration. In Configure mode, you can
create new logical drives only.

2838

Cannot create Logical Drive

The array has no free space, or the maximum

number of logical drives has been reached already.

2839

Cannot migrate Logical Drive RAID

The controller does not support RAID migration, or
migration is not possible with the current controller

configuration.

2841

Cannot extend Logical Drive

The controller does not support extension, or the

current controller configuration cannot be extended.
For example, extension is not possible if the array

has no free space.

2842

Invalid RAID

The specified RAID level is invalid or is not possible

with the current physical disk and array
configuration.

2843

Invalid Size

The specified size is invalid or is not possible with the

current configuration.

2844

Invalid Stripe Size

The specified stripe size is invalid, not supported by
the current RAID level, or not possible with the

current configuration.

2849

Invalid ClearConfigurationWithDataLoss

parameter

The valid parameters are Yes and No (default).

2850

Controller does not support Chassis Name The controller does not support setting a chassis

name.

2851

Invalid Chassis Name

The entered chassis name is invalid. Use characters

from the set a–z, A–Z, 0–9, !, @, #, *, (, ), ,, -, _, +,

:, ., /, and [space]. The name cannot end with a
space character or exceed the maximum number of

characters allowed by the controller.

2852

Invalid SSP State

The requested SSP state is not a valid SSP state.

2853

Cannot change SSP settings

The SSP settings cannot be changed for the controller
or logical drive.

2854

Invalid SSP Adapter ID

The adapter ID is not a valid adapter ID that was

detected by the controller.

2857

Invalid Surface Scan Delay

2861

Controller does not support redundancy
settings

The controller is not redundant or does not support
redundancy settings.

2864

Invalid Preferred Path Mode

The specified value for the preferred path mode is
not valid, or the controller is not available.

2865

Invalid Preferred Path

The specified preferred path is not a valid chassis

slot for an available, active controller, or the
controller is not available.

2866

Failure opening capture file

2867

Failure opening input file

2868

Failure opening error file

2877

There are no suitable spares available

HP SSA found no drives that could be used as spares
for the specified array.