Operations 98

Error code Error message

Comment or clarification

3019

Cannot create Array - no physical disks

specified

HP SSA cannot create an array unless physical disks

are specified in the input file DRIVE parameter.

3020

SSP must be enabled in order to perform this

operation

For the specified operation, HP SSA requires SSP to

be supported and enabled.

3021

Invalid connection name

3022

The connectionname cannot be removed

when the hostmode has a non-default

value.

3023

Invalid Host Mode

3024

Invalid Adapter ID

3025

This controller does not have host mode

modification capability

3026

You need to have administrator rights to
continue

3027

Another instance of HP SSA is already
running (possibly a service). Please

terminate the HP SSA application before

running HP SSA scripting.

3028

Invalid Drive Cache setting. Valid options

are ENABLE and DISABLE.

3029

Invalid or out of order Command

Verify the ordering of the commands in the input
configuration file.

3030

Invalid or missing Array for Reconfigure

Expecting a valid array in Reconfigure mode

3031

Invalid or missing Filename for Firmware
Update

The firmware filename supplied is not a valid
filename.

3032

Firmware Update Failed

The firmware flash operation on the controller failed.

3033

This controller has been configured with a

more recent version of software. To prevent
data loss, configuration changes to this

controller are not allowed. Please upgrade

to the latest version to be able to continue to
configure this controller.

Some changes to SOULAPI are not

backward-compatible. This check prevents the use of
an older version of software on a controller

configured with a newer version, possibly overriding

changes and destroying data.

3034

Operations on this Array are temporarily
unavailable while the Array is transforming.

The user requested too many simultaneous changes.
For example, the user added new disks to an array

(expand array) and changed the size or RAID level

of logical volumes on the array. The solution is for the
user to wait until the array transformation is

complete.

3035

Invalid value for NoBatteryWriteCache

A problem exists with the

NOBATTERYWRITECACHE command. Check the
supplied argument. Not all controllers support this

operation.

3036

Cannot delete Logical Drive

A problem occurred during the attempt to delete the
specified logical drive. The drive may be in use by

the OS, it may not exist, or it may not be the last

logical drive on the array.

3038

The SplitMirror command is not valid for the
specified Array

The operation is not available. Older array
controllers/firmware may not support this command.