Shrinking an array, Moving an array – HP Smart Storage Administrator User Manual

Page 63

Advertising
background image

Operations 63

where <target> is an array (or a logical drive, if the array contains only one logical drive). The forced

parameter represses any warning message prompts. If you specify a drive range, any drives in the range that
do not meet the previous criteria are not used.
If you add an odd number of drives to an array that contains a RAID 1+0 logical drive, you are prompted to
convert the RAID 1+0 logical drive to RAID 5 or RAID 6 (ADG). Adding the forced parameter to the

command prevents this prompt from appearing.
Example commands:

=> ctrl slot=3 array A add drives=1:0,1:1

=> ctrl slot=4 ld 1 add drives=allunassigned

=> ctrl slot=5 array A add drives=1:1–1:5

Shrinking an array

Some controllers may not support this option or may require a license key to enable this feature.
You can shrink the size of an array by removing a drive from an existing array. Observe the following
criteria:

After the shrink, the array must have sufficient capacity to contain all of the configured logical volumes.

You may not remove drives from the array if the resulting number of drives does not support the fault

tolerance (RAID level) of any existing logical drive. For example, if you have an array with four physical
drives and a RAID 5 logical drive, you can remove, at most, one drive, because RAID 5 requires at least

three physical drives.

If the array contains a RAID 1+0 logical drive, you can remove only an even number of drives.

If the array contains a compound RAID (RAID 50 or RAID 60) logical drive, you can remove drives only
in multiples of the number of parity groups. For example, an array with 10 physical drives and a RAID

50 logical drive can be shrunk by removing two or four drives only.

Syntax:

<target> remove drives=[#:]#:#-[#:]#:#

where <target> is an array, and the specified physical drives are being removed to shrink the array.
For example, in an existing array (array a), six drives (1e:1:4-1e:1:9) are in use. With all criteria met, you
can shrink the array to four drives by removing the last two drives with the command: <array a> remove

drives=1e:1:8-1e:1:9
Example commands:

=> array a remove drives=1e:1:12-1e:1:14

=> array b remove drives=1c:1:6-1c:1:7

Moving an array

Some controllers may not support this option or may require a license key to enable this feature.
You can move an array by designating different physical drives for the array. To move the array, each of the
physical drives where the array will reside must meet the following criteria:

It must be an unassigned drive.

It must be of the same type as the physical drives currently in the source array (for example, SATA or

SAS).

The destination drives must have sufficient capacity to hold all the logical drives present in the source

array.

Advertising