Davis Technologies TM-4000-Drag-PRO V3 n

2

0 2010

correction made.

Null Mode 0- Traction Control makes corrections

in the normal manor.

Null Mode 1- Traction Control only makes Step 1

(small) corrections within the set

RPM range.

Null Mode 2- Traction Control will not make any

corrections within the set RPM range.

The Buffer setting is another feature that can be used
to fine tune the system. The buffer sets the number
of consecutive errors required to cause a correction.
Buffer 0 will react to each error in acceleration.
Buffer 1 will require at least 2 consecutive slip
conditions to cause a correction. This is useful to
filter out small tire slips that may occur quickly, but
have no ill effect on the car.
(Buffer 1 is the default for
most applications, but some experimenting with this
setting may be useful to see what works best for you).

The Sample Rate of the unit can also be changed by
the user, however this should only be done after
consulting w/ tech support. The lower the number
the faster the Sample Rate, which makes the unit less
sensitive, but faster to react. The higher the number
the slower the Sample Rate, which makes the unit
more sensitive, but slower to react. Valid settings
are 1-5.

(Default=3)