Nitrous Express DRAG-Pro N2O User Manual
Page 18

17
Davis Technologies TM-4000-Drag-PRO V3 n
2
0 2010
changed by the user. The RPM is set in 100 rpm
increments, (example 9900 rpm, divided by 100= 99).
To change the Ending RPM value, follow these steps.
1.
Set the “Mode” dial to “9”
2.
Hold down the “Test” button
3.
Turn the power On
4.
While holding the “Test” button down, move
the “Mode” dial to the first digit of the desired Ending
RPM.
(example- 9900rpm - first digit=9 / 8500rpm - first digit =8)
5.
Release the “Test” button,
The led will flash to show the value has been
accepted.
6.
Now move the “Mode” dial to the second digit
of the desired Ending RPM, then press and release
the “Test” button.
(example- 9900rpm - sec. digit=9 / 8500rpm -
sec. digit =5)
The led will flash to show the value has been
accepted.
After about 1 second the LED will Blink to show the
value that the Ending RPM is set to. The first digit is
output followed by a short pause, then the second
digit is output.
(9900 RPM = 9,9 Blinks) (zeros are
indicated by shorter blinks)