Nitrous Express Octane Series Progressive User Manual

Page 8

Advertising
background image

SCROLL DOWN:

If you selected digital you must use the FJO GEN-3 wideband. Because this setting allows you to have up to 8 FJO
widebands on the digital data bus, you must tell the controller how many it should look for. If it does not find them, or if
one of them fails during operation, it will report an error. The Analog option only supports one wideband so this line will
only be present when set to digital.



Push the button in the area will turn grey, and scroll up or down to the correct value.
Push the control button in to save the value.


SCROLL DOWN:


This is the HI side set point for your wide-band scale. The closer this number is to your highest
number the finer the scale will be. Pushing the control button in will turn the area grey and now you
can scroll up or down to the correct value.
Push the control button in again to save.


SCROLL DOWN:


This is the HI side set point where your air fuel display will change from yellow to red. Pushing the
control button in will turn the area grey and now you can scroll up or down to the correct value.
Push the control button in again to save.




SCROLL DOWN:


This is the MID/HI side set point where your air fuel display will change from green to yellow. Pushing
the control button in will turn the area grey and now you can scroll up or down to the correct value.
Push the control button in again to save.




SCROLL DOWN:



This is the low/mid side set point where your air fuel display will change from yellow to green.
Pushing the control button in will turn the area grey and now you can scroll up or down to the correct
value. Push the control button in again to save.



SCROLL DOWN:

This is the low side set where your air fuel display will change from red to yellow. Pushing the control
button in will turn the area grey and now you can scroll up or down to the correct value. Push the
control button in again to save.


SCROLL DOWN:


This is the low side set point for your wide-band scaling. The closer this number is to your low
number the finer the scale will be. Pushing the control button in will turn the area grey and now you
can scroll up or down to the correct value. Push the control button in again to save.


Advertising