(6)
Connect oil hoses #27 (A) & #28 (B).
・
Oil line hose A goes between the center unions.
Where the 90 degree fitting is on the filter side,
and the 45 degree fitting on the engine side.
・
Oil line hose B goes between the side unions.
Where the 45 degree fittings are on each side.
※
Use the corrugated tube (#31) to cover any part of
the oil lines that might make contact with any part
of the chassis or the other oil line.
※
Refer to the Images to reference where each end
of the hoses should go.
〈
Parts used: 27, 28
,
31
〉
Optional Sensor Installation Instructions
Engine Block side
Oil filter side
・
Sections
A、B、E
(1/8PT)・・・
able to measure oil temperature and oil pressure.
・
Section
C
(1/ 8PT)
・・・
The electrical type warning meter temperature
sensor fits here.
・
Section
D
(M14×P1.5)
・・・
Mechanical type temperature sensor fits here.
A
A
A
A
B
B
B
B
E
E
E
E
D
D
D
D
C
C
C
C