― 16―

(3) Remove the secondary air control solenoid valve

hoses from the hard lines and take note which

hose goes to which hard line. Attach the

secondary air control solenoid valve to the

provided bracket #68 using the provided M5

nut/bolt #82, then install the bracket onto the

chassis cross bar using the OEM bolt.

Parts used: 68

82

(4) Connect the

5φ

hose routed under the fuel pipe

to the vacuum tank IN side

【A】

(hose with check

valve). Also connect the lower

5φ

pipe to the

air control solenoid valve

【B】

using the provided

hose

(700㎜

cut

.

Make sure the hoses are secured to prevent them

from touching the engine belts.

Parts used: 43

80

(5) Secure the hoses with cable ties.

【 A 】

5 φ

hose at the upper pipe and check

valve.

Intake Manifold and lower

5φ

pipe.

Parts used: 80

№68

Sec. Air Control Valve