GReddy TURBO KITS: Honda S2000 (AP2) 2004-06 / T518Z User Manual

Page 19

Advertising
background image

― 19―

(2)

Install suction pipe S-1 to the compressor housing

using the provided #62 gasket. Be sure that the

bracket on the pipe is positioned onto the rubber

vibration mount previously installed. Secure S-1 at

the compressor housing with the provided #90

hardware. Secure S-1 at the bracket and vibration

mount with the provided #87 nut.

Parts used:

5,

62

87

90

Install the

12φ

oil resistant hose #45 from the valve

cover breather nipple to the nipple on the S-1 suction

pipe. Use provided hose clamps #54 to secure both

ends of the hose.

Parts used: 45

54

Install the provided

1 9 φ

hose (#47) to the air

pump OUT hose using union #74. Secure the

other end of the hose to the suction pipe S-1. Use

provided #56 hose clamps to secure both ends of

the hose, as well as the end of the air pump OUT

hose (3 hose clamps used total).

Parts used: 47

56

74

№ 45

№47

№74

Zip Tie here

S-1

Rubber

Mount