APPENDIX C. ERROR MESSAGES


The following is a list of error messages and descriptions:

Added Pulse Detected!
CARD MAY NOT BE READABLE IN THE FIELD!

This message indicates that the card media may have background noise or waveform
condition in excess of ISO specifications.



Amplitude Speed Compensation Failure on Track (1,2,3)
Please Reread Card

This message indicates that there was a problem aligning speed and amplitude data.
Performing a cleaning cycle may eliminate the problem.

Blank card or card inserted incorrectly!

The tester did not detect any magnetic encoding.


Could Not Setup Unit, Track 1 data is missing or Invalid Setup Card!
or
Could Not Setup Unit, Invalid Setup Card!

or

Could Not Setup Unit, Density Factor out of range!
or
Could Not Setup Unit, SS Sensor out of range!

This group of errors indicates a problem with the setup card. Repeat setup. If problem
continues contact technical support to have a new setup card made.


CRC Check has Failed.
CARD MAY NOT BE READABLE IN THE FIELD!

Some encoding formats contain CRCs. This error indicates that the CRC or the data is
incorrect. The purpose of CRCs is similar to LRCs.