COMMUNICATIONS PARAMETERS (RS-232/RS-485):

Baud rate:

......................

9600 baud

Stop bit:

......................

1

Data bits:

......................

8

Parity: ......................

None

Flow Control:

......................

None

DISPLAY*: Optional local 2x16 characters LCD with adjustable backlight (2 lines of text).

KEY PAD*: Optional 4 push button key pad.

CE COMPLIANCE: EMC Compliance with 89/336/EEC as amended.
Emission Standard: EN 55011:1991, Group 1, Class A
Immunity Standard: EN 55082-1:1992

(* - optional feature)

Table 2.3.1 PWE Flow Meter Flow Ranges and Pressure Drop

Table 2.3.2 PWE Flow Meter wetted materials

8

FLOW RATE FOR PWE

METER

SIZES

FLOW RATE H

2

0

INLET/OUTLET

PORTS FEMALE

NPT

MAXIMUM PRESSURE DROP

[L/min]

Gal/min

Bar

PSI

PWE4

0.15-18.9 0.04-5

3/8"

1

15

PWE6

0.3-37.6

0.08-10

1/2"

1.4

20

PWE8

0.6-64.4

0.15-17

3/4"

1.4 20

PWE10

1.3-132.5

0.35-35

1"

1.4 20

WETTED MATERIALS

POLYPROPYLENE MODELS

PVDF MODELS

BODY

Polypropylene PVDF

LID

Acrylic

PVDF

PADDLE WHEEL

PVDF
Nickel Tungsten Carbide

PVDF
Zirconia Ceramic

BEARINGS

Sapphire Jewels

Sapphire Jewels

O-RINGS

EPDM

PTFE

PLATINUM RTD

316 stainless steel casing

316 stainless steel casing