Aalborg PWE Digital User Manual

Page 71

Advertising
background image

66

COMMAND

NAME

DESCRIPTION

NO.

COMMAND SYNT

A

X

COMMAND

ARGUMENT 1

ARGUMENT 2

ARGUMENT 3

ARGUMENT 4

RESPONSE

Optical

Outputs

Assigns action of the two

optical outputs. The optical

output becomes active when

the condition specified by an

Argument 2 becomes true.

Argument 2:

D

-

no action, disabled*

FL

-

low flow alarm

FH -

high flow alarm

FR -

Range between High &

Low alarms

MT

-

main tot. reading > limit

PT -

pilot tot. reading > limit

TL

-

low temp. alarm

TH

-

h

igh temp. alarm

TR

-

Range between High &

Low temp. alarms

MC

-

Manual On Control

DE

- Diagnostic

Events

8

O

1 (output #1)

2 (output #2)

D *

O1:D or O2:D

FL

O1:FL or O2:FL

FH

O1:FH or O2:FH

FR

O1:FR or O2:FR

MT

O1:MT or O2:MT

PT

O1:PT or O2:PT

TL

O1:TL or O2:TL

TH

O1:TH or O2:TH

TR

O1:TR or O2:TR

DE

O1:DE or O2:DE

MC

O1:MC or O2:MC

S (read

current

settings)

Ox:D

Main

To

talizer

Sets and controls action of the

Main flow totalizer

.

NOTE:

Main T

o

talizer reading is

stored in EEPROM (non

volatile) memor

y. Power cycle

will not affect Main T

o

talizer

reading.

9

MT

Z (Reset to zero)

MTZ

F (start totalizer

at flow %F

.S.)

MTF:<value>

L (Limit gas

volume in

current E.U.)

MTL:<value>

D (disable

totalizer)*

MT

:D

E(enable totalizer)

MT

:E

R(read current

totalizer volume)

MTR:<value>

(in current EU)

S(setting status)

MTS:Mode,Start,Limit