Section 10. Custom Keyboard Display Menus

The MenuItem instruction creates an item that displays the value of a variable
and allows the value to be edited. The MenuItem can be set up to be edited
either by keying in a new numeric value or by selecting an option from a pick
list.

MenuPick is use to create a pick list for MenuItem. A link to another user
menu can be created with the SubMenu and EndSubMenu functions.

Example Program 10-1 is an example of a CRBasic program to set-up a custom
display. It is used as a model for the instructions in this section.

Example Program 10-1:

'Declare Variables for panel temperature, two thermocouples, a [down] counter
‘and a flag to determine if the count is active or not:
Public Tpnl, Ttc(2)
Public Counter, CountFlag
'Declare constants for menu display:
Const Yes = True
Const No = False
DataTable (Temp,1,1000)

'Define DataTable Temp:

DataInterval

(0,1,Sec,10)

Average

(1,Tpnl,IEEE4,0)

Average

(2,Ttc(),IEEE4,0)

EndTable
DisplayMenu ("Example Custom Menu",1)

'Define Custom Menu:

SubMenu("Current

Temperatures")

DisplayValue("Panel

Temp",Tpnl)

DisplayValue("TC

1",Ttc(1))

DisplayValue("TC

2",Ttc(2))

EndSubMenu

SubMenu("Last 1 Min. Averages")

DisplayValue("Panel

Temp",Temp.Tpnl_Avg(1,1))

DisplayValue("TC 1",Temp.Ttc_Avg(1,1))

DisplayValue("TC 2",Temp.Ttc_Avg(2,1))

EndSubMenu

SubMenu ("Play with Down Count")

MenuItem

("Enable",CountFlag)

MenuPick

(Yes,No)

'Create a pick list with constants

MenuItem("Down

Count",Counter)

MenuPick(15,30,45,60)

'Create a pick list for Counter

'While the counter can be reloaded with the above menu item,

'using a sub menu allows slightly more descriptive text:

SubMenu("Reload

Down

Counter")

MenuItem("Pick

Count",Counter)

MenuPick(15,30,45,60)

'Create a pick list for Counter

MenuItem("Enter

No.",Counter)

'no pick list = user enters #

EndSubMenu

EndSubMenu

EndMenu
BeginProg

'Main Program

Scan

(10,mSec,100,0)

ModuleTemp

(Tpnl,1,1,100)

TCDiff

(Ttc(),2,mV50C,4,1,TypeT,Tpnl,True ,40,100,1.0,0)

If

CountFlag

Then

Counter=Counter-1
If

Counter

<=0

Then

Counter=0

EndIf
CallTable

Temp

NextScan
EndProg