Specifications, 1. nl200/201 dimensions in inches – Campbell Scientific NL200/NL201 Network Link Interface User Manual

Page 18

Advertising
background image

NL200/201 Network Link Interface

5. Specifications

General

177 g (6.3 oz)

16 x 6.73 x 2.54 cm (6.3 x 2.65 x 1 in)

FIGURE 5-1. NL200/201 dimensions in inches

Power Input

NL201: CS I/O or barrel connector jack; not powered over USB

NL200: Barrel connector jack; not powered over CS I/O or USB

Power Requirements

7 to 20 Vdc

50 mA active, 2 mA standby @ 13 Vdc

Standby power is when the IPNetPower instruction has been used

to turn off power to the Ethernet. See the CRBasic help for an

example of using the IPNetPower instruction. Note that the

IPNetPower instruction is only applicable when the NL200/201 is

configured with Bridge Mode Enabled.

Operating Temperature

Standard: –25 to +50 °C

Extended: –55 to +85 °C

Configuration

DevConfig over USB or Ethernet

Telnet console over Ethernet

Terminal menu over RS-232

CS I/O Port

SDC 7, 8, 10, 11 (does not support ME)

9600 bps to 460.8 kbps

RS-232 Port

DTE

1200 bps to 115.2 kbps

NOTE