NL200/201 Network Link Interface

8.1.1 Configuring the NL200/201

•

Connect to the NL200/201 in DevConfig (see Section 6, Configuring the

NL200/201).

•

On the NL200 tab:

o Set Bridge Mode to disable.

o Set Use DHCP to disable.

o Input the IP Address, Network Mask, and Default Gateway. These

values can be provided by your network administrator.

•

On the Network Services tab:

o Make note of the PakBus/TCP Server Port.

8.1.2 Configuring the Datalogger

The datalogger must first be configured for internet

communication (i.e., through an NL115, an NL120, a second

NL200/201, or a cellular modem).

•

Connect a serial cable from the PC COM port to the datalogger’s RS-232

port.

•

Open DevConfig. Select the device type of the datalogger (CR800,

CR1000, or CR3000), the appropriate

Communication Port, and Baud

Rate. Press Connect to connect to the datalogger.

•

On the Network Services tab:

o Under PakBus TCP Client Connections, input the NL200/201’s IP

address and PakBus TCP Server Port.

•

Press

Apply to save the changes and then close DevConfig.

9. Troubleshooting

This section covers some common problems that might be encountered when

using the NL200/201. This is not comprehensive but should provide some

insight and ability to correct simple errors without a call to Campbell Scientific

technical support.

When your Campbell Scientific software cannot establish a link to a remote

datalogger that is connected to the NL200/201, do the following:

1. Check all your power connections.

•

Your NL200/201 and any hub and/or router being used must be

connected to power. Check power indicator lights to make sure your

devices are powered.

NOTE