5 connect, 3 tcp serial server, 1 physical setup – Campbell Scientific NL200/NL201 Network Link Interface User Manual

Page 26: Connect, Tcp serial server, Physical setup, 2. bridge mode loggernet setup

Advertising
background image

NL200/201 Network Link Interface

your settings are correct, you should see the current clock of your server

and datalogger.

FIGURE 7-2. Bridge mode LoggerNet setup

7.2.5 Connect

You are now ready to connect to your datalogger using the LoggerNet Connect

screen.

7.3 TCP Serial Server

The NL200/201 can tunnel RS-232 and CS I/O serial communications over

Ethernet. Any packet sent to the configured Ethernet IP port will have the IP

layer removed, and the serial data is then directed to the serial connection.

7.3.1 Physical Setup

Using the supplied serial cable, connect the NL200/201’s CS I/O port or RS-

232 port to the datalogger’s CS I/O or RS-232 port, respectively. The NL201

will be powered if connected via CS I/O. Alternatively, power the NL200 or

NL201 through the barrel-connector jack located on the edge of the device.

Connect the NL200/201 to your network using an Ethernet cable, attaching one

end of the cable to the NL200/201’s Ethernet port and the other end to your

network. Ensure that the device is powered up by inspecting the Power LED.

16