Appendix B. Cables, Pinouts, LED Function, and Jumper

B.3 Ethernet

The Ethernet 10Base-T/100Base-TX cable should be a Category 5 or better

twisted pair cable (such as Campbell Scientific part number 13658). The two

active pairs are pins 1 and 2 and pins 3 and 6. Use only dedicated wire pairs

(such as blue/white and white/blue, orange/white and white/orange) for the

active pairs.

TABLE B-3. Ethernet Pinout

Pin

Function

1

TD +

2

TD -

3

RD +

4

Not Connected

5

Not Connected

6

RD -

7

Not Connected

8

Not Connected

B.4 USB

The USB cable is the supplied USB A to micro B style cable (Campbell

Scientific part number 27555). This is used only for device configuration.

TABLE B-4. USB Micro-B

Pin

Function

1

VBUS (Not Used)

2

Data -

3

Data +

4

N/C

5

GND

B.5 Power

TABLE B-5. Power In

Pin

Function

Center

7 – 20 VDC

Sleeve

Power GND