Appendix C. NL200/201 Settings

Ethernet Speed / Duplex Configuration

Specifies the Ethernet link speed and duplex settings.

Speed: When used as a TCP/IP serial server, the overall data-transfer

speed is largely dependent on the speed of the serial port. Setting the

Ethernet link speed to 100 Mbps will increase the overall data throughput

rate by a relatively small amount, while setting it to 10 Mbps will conserve

power.

Duplex: Setting the Duplex to “Full” allows communication in both

directions simultaneously, while setting it to “Half” allows communication

in only one direction at a time.

Setting the Ethernet Speed/Duplex Configuration to “Auto” will cause the

NL200/201 to auto-configure to the faster of the two speeds and fastest duplex

setting according to the capabilities of the network.

Admin Password

To help guard against unauthorized access to the NL200/201, it is password-

protected by the Admin Password. This password will be required to gain

access to the NL200/201 via DevConfig over TCP and telnet. The default

password is nl200. If the password setting is left blank, no password is

required to access the NL200/201. After settings are saved, the new password

will be in effect.

TCP Configuration Port Number

The default TCP port number for configuration via TCP is 6786. This entry

makes it possible for the user to change the port number used in TCP

configuration if desired. Typically, it is not necessary to change this entry

from its default. (range 1..65535)

C.2 RS-232 Tab

RS-232 Configuration

This setting controls which process will be associated with the RS-232 port.

The following values are defined:

TCP Serial Server

The device will listen for an incoming TCP connection from a remote

client. The port number of the listening connection is specified in the

“RS-232 Service Port Number” setting. Data received on the TCP

connection will be forwarded to the RS-232 port, and data received on the

RS-232 port will be forwarded to this TCP connection.

TCP Serial Client

The device will maintain a TCP client connection with a remote server.

The IP address and port number of the remote server are configured in the

settings “RS-232 TCP Serial Client IP Address” and “RS-232 TCP Serial

Client Port”. Data received on the RS-232 port will be forwarded to this

TCP connection, and data received on the TCP connection will be

forwarded to the RS-232 port. The device will attempt to open a