Example

The following example configures the maximum storm control Broadcast rate at 900 Kbits/Sec on Ethernet port 1/
g5 of a FE port.

show ports storm-control

The show ports storm-control User/Privileged EXEC mode command displays the storm control configuration.

show ports storm-control [interface]

Parameters

interface — A valid Ethernet port. (Full syntax: unit/port)

Default Configuration

This command has no default configuration.

Command Modes

Privileged EXEC mode

User Guidelines

There are no user guidelines for this command.

Example

The following example displays the storm control configuration.

Console(config)# interface ethernet 1/g5
Console(config-if)# port storm-control broadcast rate 900

Console# show ports storm-control
Port

State

Rate [Kbits/Sec]

Included

----

--------

----------------

--------------------------------------

1/g1

Enabled

70

Broadcast, Multicast, Unknown Unicast

2/g1

Enabled

100

Broadcast

3/g1

Disabled

100

Broadcast