Show copper-ports cable-length – Allied Telesis AT-S95 CLI User Manual
Page 162

Page 150
Not approved by Document Control. For review only.
Allied Telesis
Command Line Interface User’s Guide
Default Configuration
This command has no default configuration.
Command Mode
User EXEC mode
User Guidelines
The maximum length of the cable for the TDR test is 120 meter.
Example
The following example displays information on the last TDR test performed on all copper ports.
show copper-ports cable-length
The show copper-ports cable-length User EXEC mode command displays the estimated copper cable length
attached to a port.
Syntax
show copper-ports cable-length [interface]
Parameters
•
interface — A valid Ethernet port. (Full syntax: unit/port)
Default Configuration
This command has no default configuration.
Command Mode
User EXEC mode
User Guidelines
The port must be active and working in 100M or 1000M mode.
Console show copper-ports tdr
Port
Result
Length [meters]
Date
----
------
---------------
----
1/g1
OK
1/g2
Short
50
13:32:00 23 July2005
1/g3
Test has not been performed
1/g4
Open
64
13:32:00 23 July 2005
1/g5
Fiber
-
-