Setting the recording EQ

• Set the recording level adjustment to MANUAL beforehand.

(

➜ page 22) (When the recording level adjustment is

AUTO, the unit does not enter the recording standby.)

1

Press and hold [* REC] for 1 second or more.

The unit enters the recording standby.

2

Press [MENU].

3

Press +, – to select “REC EQ” and press
[
q OK] to enter.

4

Press +, – to select the recording EQ mode.

Press [F1 (CONFIRM)] to confirm the details. Press
[F1] again to return to the previous screen.
When you select modes other than “USER”, go to step

5

.

Setting when selecting “USER”:
1

After step

4

, press

[F1 (EDIT)]

150 Hz band is selected.

2

Press u, i to select the frequency band to

change, and press +, – to adjust the recording level

(±12 dB).

3

When the settings for the frequency band to change

are all complete, go to step

5

.

5

Press [q OK] to enter.

To exit the setting screen, press [F2 (CLOSE)].

The EQ mode name is not displayed after exiting the

setting screen.

Pressing [* REC] starts recording.

EQ mode

Effect and application

FLAT

This (basic) mode does not emphasise a

specific sound range.

EXTRA BASS Emphasise the bass range strongly.
BASS

Emphasise the bass range slightly.

MIDDLE

Emphasise the middle range.

BASS&TREBLE Emphasise the bass and treble ranges slightly.
TREBLE

Emphasise the treble range slightly.

EXTRA TREBLE Emphasise the treble range strongly.

USER

This mode enables adjustment of

frequency bands of 150 Hz, 500 Hz,

1 kHz, 4 kHz and 12 kHz.

(The factory setting is “FLAT”.)

*

When the recording level adjustment is AUTO, the

recording EQ does not function.

Using the recording EQ enables you to set bass, middle and treble range of recording level according to

your preferred settings for recording.

The recording EQ includes 7 types of fixed mode and the “USER” mode with which you can set the

recording level according to each frequency band.