Example: Elbow (or other flow disruption) close to the pump suction inlet

Correct

Incorrect

The correct distance between the inlet flange of the
pump and the closest flow disruption (elbow, valve,
strainer, or expansion joint) must be a least five pipe
diameters.

NOTICE:This illustration shows an incorrectly in-
stalled elbow.

NOTICE:This illustration shows a correctly installed
elbow.

Example: Suction piping equipment

Correct

Incorrect

1.

Suction pipe sloping upwards from liquid source 1.

Air pocket, because the eccentric reducer is not

2.

Long-radius elbow

used and because the suction piping does not

3.

Strainer

slope gradually upward from the liquid source

4.

Foot valve

5.

Eccentric reducer with a level top

NOTICE:This illustration shows incorrectly installed
equipment for the suction piping.

NOTICE:This illustration shows correctly installed
equipment for the suction piping.

Discharge piping checklist

Checklist

Check

Explanation/comment

Checked

Check that an isolation valve is in-

The isolation valve is required for:

stalled in the discharge line.

• Priming
• Regulation of flow
• Inspection and maintenance of the pump
See Example: Discharge piping equipment for
illustrations.