Discharge piping checklist – Goulds Pumps XHD - IOM User Manual
Page 39
Installation
Example: Elbow (or other flow disruption) close to the pump suction inlet
Correct
Incorrect
The correct distance between the inlet flange of the
pump and the closest flow disruption (elbow, valve,
strainer, or expansion joint) must be a least five pipe
diameters.
NOTICE:This illustration shows an incorrectly in-
stalled elbow.
NOTICE:This illustration shows a correctly installed
elbow.
Example: Suction piping equipment
Correct
Incorrect
1.
Suction pipe sloping upwards from liquid source 1.
Air pocket, because the eccentric reducer is not
2.
Long-radius elbow
used and because the suction piping does not
3.
Strainer
slope gradually upward from the liquid source
4.
Foot valve
5.
Eccentric reducer with a level top
NOTICE:This illustration shows incorrectly installed
equipment for the suction piping.
NOTICE:This illustration shows correctly installed
equipment for the suction piping.
Discharge piping checklist
Checklist
Check
Explanation/comment
Checked
Check that an isolation valve is in-
The isolation valve is required for:
stalled in the discharge line.
• Priming
• Regulation of flow
• Inspection and maintenance of the pump
See Example: Discharge piping equipment for
illustrations.
XHD Installation, Operation, and Maintenance Manual
37