Commissioning, Startup, Operation, and Shutdown

Deactivate the i-ALERT™ Condition Monitor

NOTICE:
Always deactivate the condition monitor when the pump is going to be shut down for an
extended period of time. Failure to do so will result in reduced battery life.

1. Touch and hold a small magnet to the condition monitor over the ITT logo until the red

LEDs blink three times.
This should take 10-15 seconds if the condition monitor is in normal operating mode and
approximately five seconds if the condition monitor is in alarm mode.

2. Remove the magnet.
If the deactivation is successful, solid red LEDs will be displayed.

Reset the i-ALERT™ Condition Monitor

NOTICE:
Always reset the condition monitor when the pump is started after maintenance, system
change, or down-time. Failure to do so may result in false baseline levels that could cause the
condition monitor to alert in error.

1. Touch a magnet to the condition monitor over the ITT logo to turn the power on.The

condition monitor begins to establish a new baseline vibration level.

Make the final alignment of the pump and driver

WARNING:

• Always disconnect and lock out power to the driver before you perform any installation or

maintenance tasks. Failure to disconnect and lock out driver power will result in serious physical
injury.

• Follow shaft alignment procedures in order to prevent catastrophic failure of drive components or

unintended contact of rotating parts. Follow the coupling or v-belt drive installation and operation
procedures from the coupling or v-belt manufacturer.

You must check the final alignment after the pump and driver are at operating temperature. For
initial alignment instructions, see the Installation chapter.
1. Run the unit under actual operating conditions for enough time to bring the pump, driver,

and associated system to operating temperature.

2. Shut down the pump and the driver.
3. Remove the coupling guardor v-belt drive.

See Remove the coupling guard or Remove the v-belt drive guard section in this chapter.

4. Check the alignment while the unit is still hot.

See Pump-to-driver alignmentfor either coupled or v-belt driven unit in the Installation
chapter.

5. Reinstall the coupling guardor v-belt drive.
6. Restart the pump and driver.